• MIT515: 5 kV with IRT and DAR, but with no memory
  • MIT525: 5 kV IRT with all test modes, including a ramp test plus advanced memory functions with recall to screen, RTC for time/date stamp of results, and USB drive to PC/PowerDB
  • MIT1025: 10 kV IRT with all test modes, including a ramp test plus advanced memory functions with recall to screen, RTC for time/date stamp of results, and USB cable interface to PC/PowerDB
  • MIT1525: 15 kV IRT with all test modes, including a ramp test plus advanced memory functions with recall to screen, RTC for time/date.

The MIT1525 is at the top of the range, and it performs insulation resistance tests up to 15 kV with a 30 TΩ maximum resistance and an accuracy of ±5 % from 1 MΩ up to 3 TΩ.

Safety rated to CAT IV, all these units are smaller and lighter than their predecessors, making them even easier to carry and store.

X
  • The S1-568 tests at up to 5 kV and can measure insulation resistance up to 15 TΩ
  • The S1-1068 operates at up to 10 kV and measures up to 35 TΩ
  • The S1-1568 has 15 kV capability and measures up to 35 TΩ

All models have a high short-circuit current of 6 mA to ensure rapid charging of items under test. The S1-568 and S1-1068 have a CAT IV 600 V safety rating, at altitudes up to 3,000 m, with the S1-1568 having CAT IV 1000 V to 4,000 m, in line with IEC 61010.

Other innovative features include the provision for remote control via a fully isolated USB port, which makes the instruments ideally suited for use in production environments, and internal storage for date- and time-stamped results. Stored results can be recalled to the display, downloaded via a Bluetooth wireless link, or accessed via the USB port.

To ensure that testing is never delayed through lack of power, these S1 insulation testers incorporate rapid-charge Li-ion batteries that give up to 6 hours of testing on a full charge for the 5 kV model and 4.5 hours for the 10 kV and 15 kV models. With just 30 minutes of charging from flat, the batteries give around one hour of testing time, and it’s also possible to operate the instrument from an AC power supply even if the battery is completely flat.

Compact and lightweight, the S1 insulation resistance testers feature a rugged dual-case design and, with the lid closed, they have an IP65 ingress protection rating. They offer timed insulation resistance (IR), dielectric absorption ratio (DAR), polarisation index (PI), dielectric discharge (DD), step voltage (SV) and ramp diagnostic tests, as well as a dedicated voltmeter function.

X
  • Immediate power frequency (50/60 Hz) insulation condition assessment with 1 Hz power factor/tan delta
  • Precise temperature correction based on insulation deterioration with patented Individual Temperature Correction (ITC)
  • Portable, lightweight, and rugged two-piece design
  • Accurate measurements under high noise conditions (765 kV substations)
Download Datasheet
X

InsuLogix® G2

Monitor acetylenu, wodoru i wilgoci

Participate in the competitionVideo Icon

Laser skupiony na zwarciach łukowych

MIT Series

For diagnostic testing and
maintenance of high voltage electrical equipment

  • Measures up to 30 TΩ
  • Safety rated up to CAT IV
  • Additional protection with dual-case design
  • Full set of diagnostic test modes
  • New PI PredictorTM

InsuLogix® G2

InsuLogix® G2 to opłacalna technologia dostępna do monitorowania wodoru i acetylenu, a także wilgoci rozpuszczonej w oleju transformatorowym, aby zapobiec potencjalnemu uszkodzeniu transformatorów.

Gaz acetylenowy sugeruje awarie o wysokiej energii wymagające pilnej uwagi.

Chroń swoje transformatory i zapobiegaj zakłóceniom za pomocą monitora InsuLogix® G2.

  • Ekonomiczne rozwiązanie do monitorowania zawierające acetylen.
  • Łatwy w instalacji i modernizacji.
  • Niskie koszty eksploatacji i konserwacji.
  • Profesjonalne wsparcie techniczne.

Book your free demo

Fill the below form to book your free demo for Megger Transformer Testing products